Att RELEASE 2 Manual de usuario

Busca en linea o descarga Manual de usuario para Accesorios De Computador Att RELEASE 2. AT&T RELEASE 2 User Manual Manual de usuario

  • Descarga
  • Añadir a mis manuales
  • Imprimir

Indice de contenidos

Pagina 1 - AT&T

AT&TMERLIN®PlusCOMMUNICATIONS SYSTEMRelease 2Installation Manual

Pagina 2

IfEach outside linehas a dial toneA line does nothave a dial toneAndThe jack for that line atthe network interface isa 1-line (RJ11-type) jackThe jack

Pagina 3 - Contents

●●●●●●●●The control unit is within 6 inches of a jack field.The network interface is available for installation or has already beeninstalled.The wirin

Pagina 4

EquipmentFour 1 1/4-inch No. 8 self-tapping screws come with the system for mountingthe unit on a wall. Regardless of the mounting surface, you will n

Pagina 5 - Introduction

Locate the back of the control unit and note the four screw holes used forsecuring the control unit to the wall (Figure 6).FIGURE 6 The control unit

Pagina 6

Remove the top cover by first unscrewing the screw located at the centerbottom of the cover. This screw is designed to stay in the hole of the coveraf

Pagina 7

FIGURE 9 Mounting the control unit on the wall.Step 1: Installing the Control Unit 11

Pagina 8

INSERT THE MODULESThe control unit comes with covers in place and with the following modulesalready installed:● Power supply module●Memory module● Lin

Pagina 9

Inserting a Line ModuleMake sure that the power switch is off and that the system is unplugged fromthe power source. Then do as follows:1Be sure the t

Pagina 10

Inserting a Voice Terminal ModuleMake sure the power is off, the control unit is not plugged into the powersource, and the covers are off. Then locate

Pagina 11

CONNECT THE CONTROLThe ac outlet should be a 117-volt, 60-Hz, 3-prong, third-wire groundedUNIT TO THE AC OUTLEToutlet. You should have an electrician

Pagina 12 - Sheet metal

©1988 AT&TIssue 1All Rights ReservedAugust, 1988Printed in USANOTICEThe information in this document is subject to change without notice. AT&T

Pagina 13

IfThe green power light doesn’t goon and the orange light on thepower switch also doesn’t go onThe green power light is on, butthe orange power switch

Pagina 14

FIGURE 14 A System Configuration Form.12345See Figure 15 and follow this procedure to connect your outside lines:Refer to your System Configuration F

Pagina 15

FIGURE 15 The control unit connected to labeled outside lines.NOTE: If you’re in an area with frequent lightning activity or severetransient voltage

Pagina 16 - ● Line module (line board)

Step 2: Wiring the Voice TerminalsPREPARATIONBefore connecting the voice terminals to the control unit, keep your SystemCONSIDERATIONSConfiguration Fo

Pagina 17

Intercom 19 and Printed Reports●●●●Printed reports require a MERLIN Plus System Data Collector and aprinter (AT&T 475 or equivalent).The MERLIN Pl

Pagina 18

VOICE TERMINAL WIRING When you planned your system, you recorded the intercom numbers forPROCEDUREspecific locations within your business on the Syste

Pagina 19

Step 3: Connecting the Voice TerminalsAny of the following voice terminal models will work at any voice terminallocation connected to your MERLIN Plus

Pagina 20

NOTE: The control unit power should be off at this point. However, ifthe power is on and the other end of this modular voice terminal cord isalready

Pagina 21

CONNECT EACH VOICESince the voice terminal module can be damaged if a modular cord isTERMINAL TO THEunplugged while there is power to the control unit

Pagina 22

FIGURE 19 Adjusting the Speakerphone volume.FIGURE 20 Verifying correct tone and light operation.Step 3: Connecting the Voice Terminals 25

Pagina 23

ContentsIntroduction1Step 1: Installing the Control UnitFCC RegulationsPrepare the Network InterfaceTest the Outside LinesMounting the Control UnitIns

Pagina 24

If the lights do not flash:Do This1 Check thegreen powerlight on thecontrol unit.2 Check thewiring run fromthe control unitto the voiceterminal.IfThen

Pagina 25

Verify Intercom NumberVerify the voice terminal’s intercom number as follows:1Touch the fifth button down (Intercom) in the leftmost row of buttons.S

Pagina 26

FIGURE 21 Verifying and labeling the intercom number.28 Step 3: Connecting the Voice Terminals

Pagina 27

AUXILIARY LINEThe auxiliary jack (the top jack) on each line module bridges and monitors theTELEPHONE outside line connected to the first line jack (t

Pagina 28

Step 4: Testing the SystemNow that your system is in place, you should test it to make sure that it’soperating properly. The following tests will help

Pagina 29

FIGURE 23 Plugging in a voice terminal to test jacks for dial tone.FIGURE 24 Testing voice terminal jacks for dial tone.Step 4: Testing the System

Pagina 30

PLACE AN OUTSIDE CALL To make sure you can use your system to place an outside call, use any voiceterminal in your system and do as follows:1Touch Sp

Pagina 31

PLACE AN INTERCOM To make sure you can use your system to place an intercom call, perform thisCALL test from one voice terminal to another in your sys

Pagina 32

345Dial the intercom number for the voice terminal where the other person iswaiting for the call.Through the speaker or your handset you’ll hear the o

Pagina 33

Step 5: Adding AccessoriesOnce you have installed your MERLIN Plus system, you may want to addaccessories to enhance its capabilities.ACCESSORY EQUIPM

Pagina 34 - Step 4: Testing the System

FCC Registration and Repair Information53Appendix A: System Connectivity Overview55Appendix B: Quick Reference Installation Requirements57Connecting t

Pagina 35

You can also add accessory equipment to the system that plugs into thecontrol unit. You can add a data collector and printer to your system tocollect

Pagina 36

FIGURE 29 MERLIN Plus system Basic Telephone Modem Interface.If you have a compatible audio system, you can connect it to the Music-on-Hold jack to p

Pagina 37

FIGURE 30 MERLIN Plus system Music-on-Hold jack.FIGURE 31 MERLIN Plus system Loudspeaker Page connected to CO line.38 Step 5: Adding Accessories

Pagina 38

FIGURE 32 MERLIN Plus system alerters.FIGURE 33 MERLIN Plus system CO line wiring accessories.Supplemental alert adapters allow you to connect alert

Pagina 39 - Step 5: Adding Accessories

Accessories that Extend Telephone RangeYou may have to provide a voice terminal power supply for a voice terminallocated more than 1000 feet from the

Pagina 40

FIGURE 35 An ln-Range, Out-of-Building protector.Step 5: Adding Accessories 41

Pagina 41

Step 6: Changing the SystemYour MERLIN Plus communications system is designed so that you can makechanges quickly and easily. You can increase your sy

Pagina 42

MOVING A VOICEYou can easily move a voice terminal from one location to another withinTERMINALyour system without having to reprogram the voice termin

Pagina 43

Jack Field Wiring SupplementA jack field is a group of jacks at the control unit location that serves as apoint of administration for telephone wiring

Pagina 44

CONSTRUCTING ANDWhile you can connect your voice terminal locations to your control unit inCONNECTING THE JACKany of several different ways, the metho

Pagina 45

IntroductionThis manual shows you how to install and test a MERLIN®PlusCommunications System, Release 2. You should perform the tasks in theorder pres

Pagina 46 - Step 6: Changing the System

●●Use spooled DIW cable.Use labels.You probably need most, if not all, of the following tools and equipment tocomplete your wiring installation. Which

Pagina 47

Constructing a Jack FieldThe control unit must be placed within 5 feet of an ac outlet, within one cordlength (7, 14, 25 feet or up to a 400 feet of s

Pagina 48 - Jack Field Wiring Supplement

5Snap as many Z601A adapters as you need into the boxes, filling theboxes from top to bottom.—If one of the jacks on the adapter has a black dot on it

Pagina 49

FIGURE 40 Running the cables.Terminating the Wiring Runs in Modular Wall JacksThere are many types of wall jacks used to terminate wiring runs. The t

Pagina 50

EXTENDING THEIf the local telephone company has provided an RJ21-type network interface,NETWORK INTERFACE TOyou cannot connect your control unit to th

Pagina 51

Add Jacks to the Jack FieldTo add jack boxes to the jack field, do the following:1234Position the jack panel box so that the door with the handle is o

Pagina 52

5Attach the telephone number directory to the inside of the jack panelbox’s left door, then close it.You should now have a single-pair modular jack in

Pagina 53

FCC Registration and Repair InformationThis equipment is registered with the FCC in accordance with part 68 of itsRules. In compliance with the Rules,

Pagina 54

Appendix A: System Connectivity OverviewFigure 42 illustrates system connectivity.FIGURE 42 Typical MERLIN Plus system connectivity.Appendix A: Syste

Pagina 55

Appendix B: Quick Reference Installation RequirementsBefore you install the control unit, make sure that the installation area meetsthe following requ

Pagina 56

Figure 1 A typical MERLIN Plus system overview.2 Introduction

Pagina 57

AC Outlet CheckCheck, or have checked by a qualified electrician, the outlet into which yourMERLIN Plus system control unit will be plugged. Check tha

Pagina 58

FIGURE 44 Mounting the control unit on the wall.Appendix B: Quick Reference Installation Requirements 59

Pagina 59

CONNECTING THEBefore connecting the control unit to the system, see Figure 45 and be sure ofCONTROL UNITthe following:● The building wiring is complet

Pagina 60

Appendix C: Grounding RequirementsProper grounding is fundamental for the MERLIN Plus CommunicationsSystem for protection against:●●●●BEFORE YOUPOWER

Pagina 61

3456789Visually verify that individual CO line protectors (carbon blocks, gastubes, etc) are in place.Set the VOM to the scale on which you can read 1

Pagina 62

EXTERNAL GROUNDINGIf the CO line protector is properly grounded and bonded to ac power, mostlightning damage will be prevented.NOTE: In areas of the

Pagina 63

FIGURE 46 Typical MERLIN Plus system grounding plan.64 Appendix C: Grounding Requirements

Pagina 64

Appendix D: Wiring Reference TablesTABLE D-1 Wiring Parts Cross Reference.PPEC614002750-D142750-D082750-D07614076120832910DescriptionNet Intf AdptrNe

Pagina 65

TABLE D-3 CO Line Wiring, 6-Position Jack, Single-Pair.RJ11 NI SpecificationD2R CordCU Line Jack SignalPinPlug PlugPin SignalColorT4GREEN433TR3RED344

Pagina 66

TYPICAL SYSTEM WIRING Figure 47 shows a typical wiring installation for a MERLIN Plus system.INSTALLATIONLocal telephone lines connect with system wir

Pagina 67

Step 1: Installing the Control UnitFCC REGULATIONSTo comply with FCC regulations, notify your local telephone company of thefollowing before permanent

Pagina 68

TABLE D-6 Material List for 8 Telephones and 3 Lines (Figure 47).Voice Terminal WiringQtyItem3351288102A Connecting Block (1 shown)65B Faceplate (1 sh

Pagina 69

Appendix E: Direct Connection WiringYou can connect your voice terminal locations in either of two ways:●Through the building wiring to a jack field a

Pagina 70 - Interface (RJ21):

FIGURE 48 Voice terminal wiring, direct connection.70 Appendix E: Direct Connection Wiring

Pagina 71

Any of the following voice terminal models will work at any voice terminallocation directly connected to your MERLIN Plus system:●●●●●●●●●5-Button voi

Pagina 72

5678Plug the cord for the new location into the corresponding control unit jackwith the voice terminal’s intercom number.Relabel the cord at the new l

Pagina 73

IndexAAccessories, 29adding, 35 – 41Accessory equipment, 35Adapter, 4-line, 50, 51RJ11-type, 3, 4RJ14-type, 3, 4Z601A, 45, 48Adding a voice terminal.

Pagina 74

MMemory module, 12Modules, inserting, 12 – 14Moving a voice terminal. See Voice terminal, movingNNetwork interface, multiline, RJ21-type, 44preparatio

Pagina 75

518-600-008

Pagina 76

The 2-line adapter has two jacks, each of which carries a single-pair line fromthe 2-line network interface jack. The 50-pin connector (attached to a

Pagina 77 - 518-600-008

TEST THE OUTSIDE LINESYou may want to test whether a dial tone is audible at the network interfaceconnection. If so, you need either a basic rotary di

Comentarios a estos manuales

Sin comentarios